The new Sindie ®+Cl R-Series model allows trace analysis of sulfur and chlorine with a single analyzer. It is the ideal solution for certifying sulfur levels in finished products, evaluating chlorine for corrosion mitigation and optimizing process parameters.
Sindie ®+Cl uses a technique known as Monochromatic Wavelength Dispersive X-Ray Fluorescence (MWDXRF), which offers exceptional reproducibility. Samples are measured directly, which means you can analyze even the heaviest hydrocarbons, such as crude oil or coke residues, without the hassles of ships, injectors, ovens or detector changes.
Characteristics:
- LIMS integration for data management and transfer.
- Customized sample presets to save data entry time and minimize data entry error on common samples
- Barcode scanner automatically completes sample name to reduce data entry time
- Storage capacity for more than 50,000 measurement results.
- Supports up to 30 calibration curves
- USB connectivity on the front and rear for connecting to a printer, keyboard, mouse and memory card
- Supports USB and network printers
- Large, easily removable side panels for ease of maintenance
- Advanced error reporting and diagnostics
- Low maintenance: no fumes or heating elements
Applications:
- Total sulfur analysis from ultra-low sulfur fuels to crude oils
- Total chlorine analysis from aqueous solutions and aromatic products to heavy and crude fuels
- For use in refinery laboratories, pipeline terminals, additive plants, and inspection laboratories
| Test Methods | ASTM D2622, D7039, D7536, D4929, ISO 20884, EN 16997, and SH / T 0842 |
| Sensitivity and Measuring Range | Sulfur: LOD: 0.4 ppm at 300 s / Dynamic Range: 0.4 ppm to 5%
Chlorine: LOD: 0.3 ppm at 300 s / Dynamic Range: 0.3 ppm to 3000 ppm |
| Dimensions (HxWxD) | 42 cm (H) x 40 cm (W) x 54 cm (D)
16.5 in (h) x 15.8 in (w) x 21 in (d) |
| Weight | 34 kg / 75 lbs |
| Display | Intuitive 10-inch touch screen |
| Power supply | 100-120 VAC, 47-63 HZ at 6.0 Amps/
200-240 VAC, 47-63 HZ at 2.5 Amps |
| Minimum sample cup volume | Traditional – 5 ml, Accucell – 1 ml |
| Sample Cup | Accu-Cell |
| Ambient temperature requirements | 5-40° C (40-104° F) |
| Optical pass-through | Vacuum |
| Excitation source | 75 W air-cooled |
| Measuring time | 10-999 s, user selectable |
| Relative humidity | 30 – 85 % |
Chlorine and Total Sulfur
ASTM D2622
ASTM D7039
ASTM D7536
ASTM D4929
ISO 20884
EN 16997
SH / T 0842
To be consulted
Pide información de Sulfur (S) and chlorine (Cl) X-ray fluorescence analyzer, New model Sindie+Cl R Series
We want to play an active role in creating a safer and more environmentally respectful future.
Related resources
Continue reading
Mandatory testing for PFAS and total fluoride in packaging starting in August 2026
Continue reading
ASTM includes Eraflash (D7094) for specifying the flash point in Jet A/A-1 fuels.
Continue reading
TOC analytical method in cleaning validations: criteria, limits and robustness of the process
Continue reading
Continue reading
Continue reading