Portable pH/Dissolved Oxygen / RDO meter suitable for all types of samples.
It has a backlit LCD display that simultaneously shows the readings of:
Dissolved Oxygen in percent saturation or concentration and temperature, plus date, time, probe status, user ID, sample ID and calibration points.
Simple operation through guided on-screen menus with key indicators for the user.
Automatic recognition of polarographic probe and optical/luminescent RDO.
Software in Spanish.
AUTO-READ function.
Stores up to 5000 readings, associated with date and time, in its non-volatile memory.
Easy download of data to PC via USB port or RS232 port with the analysis software.
Power supply: 4 AA alkaline batteries.
IP67 splash-proof protection.
The STAR A3265 model includes:
STAR A 326 Meter
ROSS Triode pH/temperature electrode (OR8107UWMMD)
Optical/luminescent dissolved oxygen probe, with stainless steel guard, 3 m cable and miniDIN connector (OR087010MD)
pH 4, 7 and 10 buffers (pack of 10 sachets of each)
Storage solution for pH electrode (OR810001)
Conductivity standard 1413 µS, 10 sachets (OR01100710)
Cleaning solution, 10 sachets (OR911110)
Carrying case.
Alkaline batteries (4 x AA)
Dimensions: 24cm x 10cm x 6.5cm (length x width x height)
Weight: 0.5 kg
Power supply: 4 AA alkaline batteries
Autonomy: 800hrs.
Inputs: Oxygen and Temperature probe: 9-pin-mini-DIN
Outputs: RS232, USB
Measuring modes: pH, mV, relative mV (RmV) or ORP with temperature; dissolved oxygen as % saturation or mg / L with temperature and barometric pressure
Calibration points: 1-point relative mV (RmV) mode, 1-point ORP mode
Calibration points (pH): 1 to 5
Channels: 2
Operating temperature: 5°C to 45°C (ambient)
Temperature probe calibration: 1-point temperature compensation calibration
Temperature range: -5.0°C to +105.0°C
Temperature resolution: 0.1°C, 0.1°F
Temperature selection: manual or automatic with ATC temperature probe
Parameter specifications:
pH:
Range: -2,000 to 20,000
Resolution: 0.1 / 0.01 / 0.001
Accuracy: ± 0.002
Calibration points: Up to 5 points.
Edit Calibration: Yes.
mV/RmV:
Range: ± 2000.0 mV
Resolution: 0.1
Accuracy: ± 0.2 mV or 0.05% of reading
REDOX mode: Yes.
Temperature:
Range: -5 to 105 ºC
Resolution: 0.1
Accuracy: ± 0.1
Offset compensation: 1 point
Dissolved oxygen:
Concentration – Polarographic:
Range: 0 to 90 mg/l
Resolution: 0.01 – 0.1
Accuracy: ±0.2
% Saturation – Polarographic:
Range: 0 to 600
Resolution: 0.1 – 1
Accuracy: ±2%.
Concentration – RDO:
Range: 0 to 50 mg/l
Resolution: 0.01 – 0.1
Accuracy: >8 mg/l: ±0.1
From 8 to 20 mg/l: ±0.2
From 20 to 50 mg/l: 10% of the reading
% Saturation – RDO:
Range: 0 to 500
Resolution: 0.1 – 1
Accuracy: ±2%.
Automatic barometric pressure correction: 450.0 to 850.0 mm Hg
Manual correction of salinity factor: 0 to 45 ppt
Calibration: Air-saturated water, water-saturated air, manual (Winkler) and zero.
Probe: Polarographic or RDO.
Temperature:
Range: 0 to 50 ºC (32 to 122 ºF)
Resolution: 0.1
Accuracy: ± 0.1
Offset calibration:1 point
pH/Dissolved Oxygen / RDO and T
pH electrodes
Selective electrodes
Dissolved oxygen probes
RS 232 communications cable
Carrying case
Maintenance kits for dissolved oxygen probes
pH calibration buffers
Calibration pattern redox potential
Electrode cleaning solutions
Filling solutions and electrode preservation
Star Navigator Plus Software