The Elite Plus range of reverse osmosis units satisfies key applications requiring between 500 and 5000 liters per hour of RO (reverse osmosis) grade water. To reduce operating costs, Elite Plus incorporates the latest "low energy" membranes and to reduce overall footprint is constructed with integral 5 μm pre-filters. The unit's stainless steel frame and compact dimensions allow for easy transportation.
Characteristics:
Applications:
|
Model |
500 |
1000 |
1500 |
2000 |
2500 |
3000 |
4000 |
5000 |
|
Dimensions |
||||||||
|
Height (mm) |
1220 |
1220 |
1220 |
1330 |
1330 |
1475 |
1475 |
1475 |
|
Width (mm) |
625 |
625 |
625 |
740 |
740 |
850 |
850 |
850 |
|
Length (mm) |
1250 |
1250 |
1250 |
1575 |
1575 |
1575 |
1575 |
1575 |
|
Working weight (kg) |
90 |
130 |
190 |
200 |
240 |
380 |
420 |
460 |
|
Shipping weight (kg) |
60 |
90 |
120 |
155 |
175 |
290 |
330 |
370 |
|
Performance |
||||||||
|
Permeate flow rate @ 10°C (m3/hr) |
0.5 |
1 |
1.5 |
2 |
2.5 |
3 |
4 |
5 |
|
Drainage flow @ 10°C (m3/hr) |
0.25 |
0.5 |
0.75 |
1 |
1.25 |
1.5 |
2 |
2.5 |
|
Typical recovery |
60-75% |
|||||||
|
Average salt rejection |
96-98% |
|||||||
|
Installation requirements |
||||||||
|
Feeding |
230V/1ph/50-60Hz |
400V+N+E/3ph/50-60Hz |
||||||
|
Feed Connections (inch) |
½ |
¾ |
¾ |
1 |
1 |
2 |
2 |
2 |
|
Drainage connection (inch) |
½ |
¾ |
¾ |
1 |
1 |
1¼ |
1¼ |
1¼ |
|
Permeate connection (inch) |
½ |
¾ |
¾ |
1 |
1 |
1½ |
1½ |
1½ |
*Feed water requirements: TDS max. 1000 ppm, total hardness <4 mg/l as CaCO3, free chlorine <0,1 ppm, SDI <3, temperature 5-350 C, pressure 2-6 bar
Water Purification
Reverse Osmosis
Consult
Pide información de Large reverse osmosis unit Elite Plus model
We want to play an active role in creating a safer and more environmentally respectful future.
Related resources
ASTM includes Eraflash (D7094) for specifying the flash point in Jet A/A-1 fuels.
Continue reading
TOC analytical method in cleaning validations: criteria, limits and robustness of the process
Continue reading
Continue reading
Continue reading
Indicated Cetane Number (ICN) vs. Cetane Index (CI)
Continue reading
Efficient and Non-Corrosive Disinfection Technology for the Pharmaceutical Industry
Continue reading