High-precision moisture analyser, model Tracer2+

Description

Specifications

Parameters

Accessories

Descargas

Ultra-high-purity moisture analyser for semiconductor manufacturing processes, inert and speciality gases, component and system testing, and laboratory research applications, with a measurement range in parts per billion. Designed for critical applications involving ultra-pure gases. Featuring NIST-validated P₂O₅ electrolytic technology and detection down to 0.7 ppbV, it offers direct, absolute and drift-free measurement, ideal for processes where moisture is a key determinant of quality and performance.

Its compact design, fast response time (up to 50 per cent faster than its predecessor) and the absence of periodic calibrations make it a robust, reliable and low-operating-cost solution for industrial, electronics and laboratory environments.

Key features:

  • Ultra-trace detection: from 0.7 ppbV with optional Heart cell; 1.0 ppbV with standard cell
  • Absolute technology: measurement by electrolysis in accordance with Faraday’s Law, with no drift and no need for calibration.
  • Fast response: optimised electronics, low-volume regulator and minimal gas path; 50% faster wet-up and dry-
  • Low cost: no annual recertification, no permeation tubes or compressed air; minimal maintenance.
  • Compact and flexible design: available as a standalone unit or in a 19’’ rack (DUO version for two simultaneous lines).
  • Intuitive to use: 5-key keypad, VFD display and guided menus; ready to operate straight from the factory.
  • Stability during transport: no need for stabilisation, recalibration or reconfiguration when moving between measurement points.
  • Online verification: simply check flow and current to comply with ISO 9001.

 

  • Detection Limit (LDL): 0.7 ppbV with Heart cell (optional); 1.0 ppbV with Standard cell
  • Operating Range (for inert gases): Inert Gases: 0 -2000 ppbV; Oxygen: 0 -1200 ppbV; Hydrogen: 0 -500 ppbV
  • Accuracy:
    • Inert Mode: 4% of reading or ± 4 ppb, whichever is greater of reading
    • O2/H2 Mode: For use in gases containing substantial amounts of Hydrogen or Oxygen, including Clean Dry Air (CDA). When the value is < 50 ppbV, the accuracy is 6% or ± 6 ppbV, whichever is greater. When the value is > 50 ppbV, the accuracy is 2% of reading or ± 20 ppbV, whichever is greater.
  • Cell type (P2O5): RILR, RTLR* NOTE: For sub-ppbV, please specify as Heart cells
  • Gas Matrices Library: Inert gases, Oxygen, Hydrogen and others, including gas mixtures. For other gases, please consult factory. *For Oxygen and Hydrogen the RTLR cell is required.
  • Inlet Pressure: 30-150 psig (2.1 – 10.3 barg).
  • Operating (Ambient) Conditions: 10° to 40° Celsius, 50° to 104° Fahrenheit, 20% to 80% RH, non-condensing, non-corrosive atmosphere. Optimal performance is achieved when temperature is maintained within ± 2°C
  • Flow Rate: 1200 sccm minimum
  • Display unit options: ppbV
  • Gas Connections: Inlet: 1/4” VCR, Outlet: 1/8” compression. Bypass outlet 1/8” compression. Purge outlet 1/8“ compression.
  • Signal Output: (Field Configurable Isolated 0-5 VDC or Isolated Current Output 4-20mA, 0-20mA, or 0-24mA) RS – 232 Communications – Standard
  • Alarms: One Form-C mechanical relay to monitor the cell response, flow, and dry time-out alarms
  • Electrical: 100 – 240 VAC, 50/60 Hz
  • User Interface: 5-key Membrane Keypad. 2-line x 20-character Vacuum Fluorescent Display (VFD).
  • Weight: 27 lbs. (12.3 kg)
  • H x W x D: 7” x 8” x 14” (17.8 cm x 20.3 cm x 35.6 cm)
  • Mounting: Stand alone; Optional 19” Rack Mount – Size: 7”x 19” x 17” (17.8 cm x 48.3 cm x 43.2 cm)
  • Approvals: CE Mark

Moisture in gases

Consult