The M-i is a palm-sized device that provides continuous, drift-free on-line moisture analysis in the range of 0.5 ppm to 1000 ppm. The compact or “mini” sensor is based on electrolytic technology (P2 O5). The M-i measures 5.10 inches high and 2.56 inches wide. The device requires no calibration, no consumables and its sensor is fully recyclable.
It is a Moisture Analyzer specifically designed for application in production, purification, filling and final product control of industrial gases.
Available versions:
Features:
– Phosphorus Pentoxide (P2O5) measuring cell.
– PC connection via RS232.
– Complies with the requirements of the European Pharmacopoeia.
– Requires regulation of flow and pressure external to the equipment.
| Specifications: | |||
| Detection limit (LDL): | 0.5 ppmV | ||
| Operating range: | 0-1000 ppmV | ||
| Accuracy: | ±5% of reading or 0.4 ppmV, whichever is greater. | ||
| In Oxygen: ±10% of reading or 3 ppmV, whichever is greater | |||
| Cell type (P2O5) | APR, APO*, or APRH* | ||
| Gas Matrix Library: | Inert gases, Oxygen, Hydrogen and others, including gas mixtures. For other gases consult factory. | ||
| *For Oxygen (mixtures) APO cell is required and Hydrogen (mixtures) APRH cell. | |||
| Inlet pressure: | Uber M-I Mounting: 3-100 psig (0.2 – 6.9 barg) (Lower available)
Uber RAK and Uber GO: 10-100 psig (0.7 – 6.9 barg) |
||
| Operating
Conditions (ambient): |
0°C to +60°C (32°F to +140°F), maximum RH 80 % non-condensing. |
||
| Flow rate: | Cell: 100 sccm
Bypass 1000 sccm |
||
| Display options: | ppmV, or ºC or ºF dew point (factory set). | ||
| Gas Connections: | Inlet: 1/8″ compression; Outlet: 1/8″ compression; Bypass outlet: 1/8″ compression. | ||
| Signal output: | 4-20 mA current supply, RS-232 communication (With MEECO software). | ||
| Alarms: | Two (2) user adjustable humidity levels (with MEECO software). | ||
| Voltage: | 24 V DC input | ||
| User interface: | 5-digit LCD display | ||
| Weight: | 0.5 kg (1.1 lbs.) | ||
| H x W x D: | Uber M-I Mounting: 4.94″ H x 2.75″ W x 2.28″ D ((12.55 cm H x 6.99 cm W x 5.79 cm D) Uber RAK: 7″ x 8.19″ x 14.66″ (17.78 x 20.80 x 37.24 cm). | ||
| Mounting: | UBER LAB – tabletop model, UBER GO – Pelican Premier case. | ||
Humidity in gases
To be consulted
Pide información de Compact absolute moisture analyzer, model Uber M-I
We want to play an active role in creating a safer and more environmentally respectful future.
Related resources
InnovaPrep solutions for microbiological detection in critical environments
Continue reading
ASTM D93-25: Standard update to improve traceability of the flash point
Continue reading
High-precision temperature control with a commitment to the environment
Continue reading
The lubricity of methanol: a critical parameter for the marine sector
Continue reading
Cannon CAV™ 5: the most advanced automatic viscometry solution for quality control
Continue reading
Cleaning validation and contamination control in the pharmaceutical industry
Continue reading