Combustion Analyzer associated to Ion Chromatography. New model AQF-5000V

Description

Specifications

Parameters

Standards

Accessories

Descargas

  • Simple combustion: No combustion programmes are required. By introducing the liquid sample into the unit at low speed, anyone can carry out the combustion easily and safely.
  • Capability to analyse samples with concentrations below 1 ppm: Through serial combustion, it is possible to burn large quantities of liquid samples.
  • Capability to measure halogens and sulphur simultaneously.
  • Space-saving design.
  • Easy maintenance: Thanks to the use of a hinged electric furnace, with a door located at the front of the combustion section, maintenance of the unit and the installation and removal of reaction tubes have been made easier.

AQF5000V Automatic combustion furnace

Parameter Specification
Target samples Liquids (gases require a specific injector)
Furnace Electric, open type, double section
Gases Argon ≥ 99.98% (0.3 ± 0.1 MPa) / Oxygen ≥ 99.7% (0.3 ± 0.1 MPa)
Power supply 100/115/230/240 VAC, 50/60 Hz, 1000 VA
Dimensions     320 × 430 × 500 mm
Weight      25 kg

 

 ASC‑550L Autosampler

Parameter Specification
Injection method Gas-tight microsyringe (25, 50, 100, 250 µL)
Containers  2/4/6 mL vials with septum
Capacity 50 vials (2/4/6 mL) or 105 vials (2 mL)
Power supply 100/115/230/240 VAC, 50/60 Hz, 180 VA
Dimensions  460 × 320 × 470 mm
Weight 16 kg

 

AOF – PFAS

  • ASTM D7359
  • ASTM D7994
  • UOP 991
  • UOP 1001
  • ASTM D8150
  • ASC-550L: Automatic liquid sample changer. It uses microsyringes to perform all operations related to liquid samples fully automatically: dosing, injection and rinsing. It has a capacity of 50 sample vials and enables the entire process to be automated, from sampling to measurement and data processing.
  • ES-500: External liquid selector. Allows automatic switching between six types of calibration solutions and feeding them into the ion chromatograph. Its integration into the absorption unit saves space.
  • CM-500: Combustion monitor. The combustion monitor measures the oxygen concentration in the combustion gases. By synchronising the position of the shuttle with the oxygen concentration, combustion conditions can be easily optimised. Its integration into the absorption unit saves space.
  • SP-C: Syringe pump unit for calibration curves. It allows calibration solutions of multiple concentrations to be prepared automatically from a single calibration solution.
  • STC-500L: Liquid sample temperature controller. When coupled with the automatic liquid sampler (ASC-550L), this device allows the temperature of vials (samples) and gas-tight microsyringes to be controlled. It has two modes: cooling mode and heating mode.

For other accessories, please contact us.