Bioburden rapid bioburden analyzer "Bioburden".

Description

Specifications

Parameters

Accessories

The new Sievers Bioburden Rapid Analyzer model Soleil is based on a high-throughput flow cytometer to quantify bioburden in less than 45 minutes. 
Compared to classical flow cytometry, we can analyze large fluid volumes(8 ml/min) almost in real time and, using a unique combination of viability staining, we can distinguish viable cells [bacteria and fungi (yeast and mold)] from non-viable ones (particles) that require days to be visible with classical methods.
The limit of detection is 1 cell/100 ml while the limit of quantification is <10 cells/100 ml of sample.
Simple sample matrices (e.g. WFI, PW, weak salt buffers) can be analyzed as is or with dilutions, thus solving any interference problems, while more complex ones (e.g. cell culture media) require evaluation based on their characteristic physicochemical properties with focused experiments. 
The R&D team has used these applications in a variety of challenging matrices (e.g. enzymes, detergents, culture media, cosmetics).
The range of applications is wide as it can be used in different key processes to obtain a fast and accurate Bioburden result: 

  • Critical Control Points for Water Circuits (PW/WFI)
  • Quality control of water for pharmaceutical uses
  • Cleaning validation sample
  • Raw materials
  • On-line monitoring of process intermediates
  • Environmental and personnel monitoring
  • Food and beverage industry
  • Medical devices

 Soleil can be used both in the laboratory and at-line in production.

Operating specifications:

Range

<10 biotics/100 ml - 10 000 biotics/100 ml

Type of example

Discrete random sample

Screen reading

Biotics/100 mL

Calibration

Normally stable for 12 months

Analysis time

< 45 minutes Total time to result (TTR)

Instrument sample flow rate

8 ml/min

Sample temperature
(Driven by integrated incubation)

35-39 °C (95-102.2 °F)

Ambient temperature

17-30 °C (63-86 °F)

Sample pressure

N / A

Analyzer specifications:

Exits

USB port, Ethernet TCP/IP

Display

Touch screen for 14″ laptop (1920×1080)

Feeding

100-240 V~, 50-60 Hz, 165 VA

Fuses

2x T 5A 250 VAC

Replace with fuse of the same type and size Device inlet 5×20 mm size

Laser (Class 1)

Wavelength: 488 nm

Maximum power: 135 mW

Dimensions

Width: 48.3 cm (19 in.)

Depth: 43.2 cm (17 inches)

Height (without laptop): 43.2 cm (17 inches)

Weight

18.1 kg (40 lbs)

Classification of the casing

IP30

Safety certifications

ETL, CE, UKCA, FCC, CSA 22.2

 
Environmental Specifications:

Maximum relative humidity

0-85%, non-condensing

Maximum altitude

3,000 m (9,800 ft)

Degree of contamination