The CAV-X is designed to scale with your lab’s varying capacity and temperature requirements. It offers enhanced flexibility and a future-ready feature set. Features include support for all tray/vial options, variable temperature range and options such as optical sensors and Vial Wash. These allow the system to adapt easily as test needs change.
CAV-X is best for multi-product labs that need flexible configuration and room to adapt as testing requirements change.
Viscosity meter adjustable within a range of +15 to +150°C.
Versatile viscosity meter. It can be configured to suit specific requirements, with accessories, a heated carousel, etc.
Features:
| Dimensions (W x D x H) | 21.6 cm x 63.5 cm x 75 cm (8.5 in x 25 in x 29.5 in) |
|---|---|
| Shipping Dimensions (W x D x H) | 82 cm x 51.5 cm x 98 cm (32.25 in x 20.25 in x 38.5 in) |
| Shipping Weight (With All Items) | 73 kg (161 lb) |
| Maximum Throughput | Up to 6 samples per hour |
| Sample Capacity | 10/20/18 |
| Viscosity Range | 0.5 mm2 /s (cSt) to 10,000 mm2 /s (cSt) in 100-fold increments (depending on viscometer tube selection). Fast run tubes are also available. |
| Timing Resolution | 0.001 s (timing accuracy to ± 0.001 s) |
| Temperature Range and Accuracy | 40 °C to 100 °C ± 0.01 °C 15 °C to 100 °C ± 0.01 °C (temperatures within 5 °C of ambient and below require the low temperature bath option) Up to 150 °C, ± 0.03 °C (with high temp bath) |
| Minimum Sample/Solvent Volume | 8 ml sample /15 ml solvent per test; As little as 3 ml with fast run tubes |
| Operating Conditions | 15 °C to 30 °C, 10% to 75% relative humidity (non-condensing), installation Category II; Pollution Degree 2 |
| Electrical Specifications | 85 to 265 VAC, 50/60 Hz; 600 watts power consumption |
| Compliance | CE Mark; EMC directive (2014/30/EV); Low voltage directive (2014/35/EC); HI-POT (1900 VDC, 60 sec.); ROHS |
Kinematic viscosity
ASTM D445
ASTM D446
Pide información de Automatic Viscometer CAV-X model
We want to play an active role in creating a safer and more environmentally respectful future.
Related resources
ASTM D93-25: Standard update to improve traceability of the flash point
Continue reading
High-precision temperature control with a commitment to the environment
Continue reading
The lubricity of methanol: a critical parameter for the marine sector
Continue reading
Cannon CAV™ 5: the most advanced automatic viscometry solution for quality control
Continue reading
Cleaning validation and contamination control in the pharmaceutical industry
Continue reading
Measurement Technologies for Sustainable and Safe Water Management
Continue reading