ASTM D93-25: Standard update to improve traceability of the flash point
Continue readingDescription
Specifications
Parameters
Standards
Accessories
Descargas
Videos
The CAV-R is the most advanced member of the CAV 5 family, built for laboratories that run a broad variety of samples. It features Tray Heat and TargetHeat, the widest-range temperature capability, three-solvent support, plus the Vial Wash and optical sensor options. Making the CAV-R optimized for the most challenging materials.
The CAV-R delivers the full power of the CAV 5 platform and is best for those customers who need the widest testing range for the most difficult applications.
Features:
| Dimensions (W x D x H) | 21.6 cm x 63.5 cm x 75 cm (8.5 in x 25 in x 29.5 in) |
|---|---|
| Shipping Dimensions (W x D x H) | 82 cm x 51.5 cm x 98 cm (32.25 in x 20.25 in x 38.5 in) |
| Shipping Weight (With All Items) | 73 kg (161 lb) |
| Maximum Throughput | Up to 6 samples per hour |
| Sample Capacity | 10/20/18 |
| Viscosity Range | 0.5 mm2 /s (cSt) to 10,000 mm2 /s (cSt) in 100-fold increments (depending on viscometer tube selection). Fast run tubes are also available. |
| Timing Resolution | 0.001 s (timing accuracy to ± 0.001 s) |
| Temperature Range and Accuracy | 40 °C to 100 °C ± 0.01 °C 15 °C to 100 °C ± 0.01 °C (temperatures within 5 °C of ambient and below require the low temperature bath option) Up to 150 °C, ± 0.03 °C (with high temp bath) |
| Minimum Sample/Solvent Volume | 8 ml sample /15 ml solvent per test; As little as 3 ml with fast run tubes |
| Operating Conditions | 15 °C to 30 °C, 10% to 75% relative humidity (non-condensing), installation Category II; Pollution Degree 2 |
| Electrical Specifications | 85 to 265 VAC, 50/60 Hz; 600 watts power consumption |
| Compliance | CE Mark; EMC directive (2014/30/EV); Low voltage directive (2014/35/EC); HI-POT (1900 VDC, 60 sec.); ROHS |
Kinematic viscosity
ASTM D445
ASTM D446
Pide información de Automatic Viscometer CAV-R model
We want to play an active role in creating a safer and more environmentally respectful future.
Productos Relacionados
New automatic Cold Crancking Simulator CCS2100-G6
Viscosity Standards
Automatic Viscometer CAV-D model
Automatic Viscometer CAV-X model
Automatic Viscometer for Polymers model Mini-PV
Automatic Viscometer for Polymers model MiniPV-HX
UltraVis® 192 solvent-free high-speed kinematic viscometer
High temperature high shear viscometer model HTHS
Related resources
ASTM D93-25: Standard update to improve traceability of the flash point
Continue reading
High-precision temperature control with a commitment to the environment
Continue reading
The lubricity of methanol: a critical parameter for the marine sector
Continue reading
Cannon CAV™ 5: the most advanced automatic viscometry solution for quality control
Continue reading
Cleaning validation and contamination control in the pharmaceutical industry
Continue reading
Measurement Technologies for Sustainable and Safe Water Management
Continue reading