Analyzer for automated measurement of adsorbable organic halogens to assess the quality of water, sludge or solids for contamination by organic halides (chlorine, bromine, iodine) adsorbed on activated carbon. The possible toxic effect of AOX on humans, animals, plants and microorganisms can be prevented by monitoring with AOX-400.
Characteristics:
| Model | Automatic Organic Halogen Analyzer Model AOX-400 |
| Application measures | River water, industrial effluents, soil, etc. |
| Sample types | Solid (AOX: aqueous liquid sample adsorbed on activated carbon).
Liquid (EOX: extraction) |
| Method of analysis | Oxidative pyrolysis / Columbiometry |
| Oven temperature | 300 – 1000 °C (recommended 950 °C |
| Introduction shows | Introduction through the open top of the combustion tube.
AOX: Injection of the sample with the activated carbon in the column through a punch (column method). Introduction of the frit with the sample adsorbed on the activated carbon (Stirring method). EOX: Direct injection with syringe |
| Range measured | Total Organic Halogens: 0.1 to 50 μg |
| Sample quantity | Samples AOX: 50 mg approx, EOX: Less than 200 μl |
| Measurement time | Less than 10 min/measurement (for 2 μg values) |
| Number of samples | Frit: 30 samples Column: 60 samples
EOX: 40 samples (Size 2 mL vials with septum) |
| Gas | Using AIR200, no cylinder air supply is required AOX: Air (800 ml/min)
ECOX: Air (100 ml/min) + Oxygen (300 ml/min) |
| Working conditions | 15 to 35 °C, below 75% humidity (non-condensing) |
| Power supply | AC 100/115/230/240 V, 50/60 Hz, 960 VA |
| Dimensions Weight | AOX-400: Approx. 460 x 420 x 560 mm (width x depth x height) / approx. 37 Kg
SI-400: Approx. 200 x 305 x 410 mm (W x D x H) / approx. 7 kg (7 lbs.) AIR-200: Approx. 100 x 400 x 220 mm (width x depth x height) / approx. 5 Kg |
| Data control devices | PC compatible with Windows ® |
Sampler:
| Stirring method | Set Frits |
| Column method | SI-400 + set columns |
| EOX | SI-400 + EOX set |
ISO 9562
DIN EN 1485
EPA 9020
DIN 38414-H1
Consult
Pide información de Automatic Organic Halogen Analyzer AOX-400
We want to play an active role in creating a safer and more environmentally respectful future.
Related resources
Dew Point measurement: how to control residual moisture in industrial processes
Continue reading
Our thanks for the Marta Mayordomo Award
Continue reading
New reference standards certified at –40 °C for Jet Fuel testing
Continue reading
InnovaPrep solutions for microbiological detection in critical environments
Continue reading
ASTM D93-25: Standard update to improve traceability of the flash point
Continue reading
High-precision temperature control with a commitment to the environment
Continue reading