Automatic Organic Halogen Analyzer AOX-400

Description

Specifications

Parameters

Standards

Accessories

Descargas

Videos

Analyzer for automated measurement of adsorbable organic halogens to assess the quality of water, sludge or solids for contamination by organic halides (chlorine, bromine, iodine) adsorbed on activated carbon. The possible toxic effect of AOX on humans, animals, plants and microorganisms can be prevented by monitoring with AOX-400. Characteristics:
  • Fastest AOX Analyzer on the market
  • High sample throughput
  • Available and flexible in the 3 injection modes:
    • Column method
    • Stirring method
    • EOX
  • Easy maintenance due to open top furnace concept
  • Low operating costs due to exclusive use of air as combustion gas
  • Unique suction system
  • Stable and highly accurate measurement results
  • Reduced design
  • Intuitive and user-friendly software
 
Model Automatic Organic Halogen Analyzer Model AOX-400
Application measures River water, industrial effluents, soil, etc.
Sample types Solid (AOX: aqueous liquid sample adsorbed on activated carbon).

Liquid (EOX: extraction)

Method of analysis Oxidative pyrolysis / Columbiometry
Oven temperature 300 – 1000 °C (recommended 950 °C
Introduction shows Introduction through the open top of the combustion tube.

AOX: Injection of the sample with the activated carbon in the column through a punch (column method). Introduction of the frit with the sample adsorbed on the activated carbon (Stirring method).

EOX: Direct injection with syringe

Range measured Total Organic Halogens: 0.1 to 50 μg
Sample quantity Samples AOX: 50 mg approx, EOX: Less than 200 μl
Measurement time Less than 10 min/measurement (for 2 μg values)
Number of samples Frit: 30 samples Column: 60 samples

EOX: 40 samples (Size 2 mL vials with septum)

Gas Using AIR200, no cylinder air supply is required AOX: Air (800 ml/min)

ECOX: Air (100 ml/min) + Oxygen (300 ml/min)

Working conditions 15 to 35 °C, below 75% humidity (non-condensing)
Power supply AC 100/115/230/240 V, 50/60 Hz, 960 VA
Dimensions Weight AOX-400: Approx. 460 x 420 x 560 mm (width x depth x height) / approx. 37 Kg

SI-400: Approx. 200 x 305 x 410 mm (W x D x H) / approx. 7 kg (7 lbs.)

AIR-200: Approx. 100 x 400 x 220 mm (width x depth x height) / approx. 5 Kg

Data control devices PC compatible with Windows ®

Sampler:

Stirring method Set Frits
Column method SI-400 + set columns
EOX SI-400 + EOX set

 

  • AOX – Adsorbable Organic Halogens
  • EOX – Extractable Organic Halogens

ISO 9562

DIN EN 1485

EPA 9020

DIN 38414-H1

Consult

Pide información de Automatic Organic Halogen Analyzer AOX-400

We want to play an active role in creating a safer and more environmentally respectful future.