ASTM includes Eraflash (D7094) for specifying the flash point in Jet A/A-1 fuels.
Continue readingDescription
Specifications
Parameters
Standards
Accessories
Descargas
Videos
It complies with ASTM D7153 and IP529 test methods, offering the highest accuracy available for the determination of the Freezing Point of Jet Fuel.
Performs results in perfect correlation with manual methods such as: ASTM D 2386, IP 16, ISO 3013 and JIS K2276.
Ultra-compact design utilizing a patented cooling system, allowing flexible and even portable use for accurate determination of the instantaneous Freezing Point below -120ºC (-184ºF).
The equipment does not require any type of cooling liquid connection, thus eliminating the heat and noise caused by external cooling systems such as circulating baths.
Internal cooling and cleaning system.
Touch screen.
The OptiFZP can store:
Temperature range: < -100°C (-148°F) - °C or °F configurable
Cooling: Internal
Detection: Optical detection
Operator time: 0.5 minutes / assay
Assay duration: 15 minutes
Sample volume: 10 ml, including volume for cleanup
Sample injection: 10 or 20 ml disposable syringes
Cleaning: Self-cleaning operation – No cleaning required
Display: 7.4″
Calibration: Automatic temperature calibration routine.
Possibility to enter temperature correction table at 10°C intervals. Programmable calibration frequency.
Memory: 50 last results, unlimited connected to PC
Data output : 2 x USB
1 x Series
1 x Ethernet
Dimensions (W x D x H): 250 x 60 x 27 Cm
Weight: 25 kg
Power supply: 100 – 240V; 200W; 50/60 Hz
Crystallization Point (Freezing Point)
According to standards: ASTM D7153 – IP529 – DEF STAN 91-91
Correlation with: ASTM D2386 – IP16 – ISO3013 – JIS K2276
Certified patterns for crystallization point
Bar code scanner for sample number entry
Syringes
Certified temperature probe
Ethernet cable
RS232 cable
Other accessories, Consult us
Pide información de Automatic crystallization point analyzer (Freezing Point) model OptiFZP
We want to play an active role in creating a safer and more environmentally respectful future.
Related resources
ASTM includes Eraflash (D7094) for specifying the flash point in Jet A/A-1 fuels.
Continue reading
TOC analytical method in cleaning validations: criteria, limits and robustness of the process
Continue reading
Continue reading
Continue reading
Indicated Cetane Number (ICN) vs. Cetane Index (CI)
Continue reading
Efficient and Non-Corrosive Disinfection Technology for the Pharmaceutical Industry
Continue reading