Dew Point measurement: how to control residual moisture in industrial processes
Continue readingDescription
Specifications
Parameters
Standards
Accessories
Descargas
Videos
It complies with ASTM D7153 and IP529 test methods, offering the highest accuracy available for the determination of the Freezing Point of Jet Fuel.
Performs results in perfect correlation with manual methods such as: ASTM D 2386, IP 16, ISO 3013 and JIS K2276.
Ultra-compact design utilizing a patented cooling system, allowing flexible and even portable use for accurate determination of the instantaneous Freezing Point below -120ºC (-184ºF).
The equipment does not require any type of cooling liquid connection, thus eliminating the heat and noise caused by external cooling systems such as circulating baths.
Internal cooling and cleaning system.
Touch screen.
The OptiFZP can store:
Temperature range: < -100°C (-148°F) - °C or °F configurable
Cooling: Internal
Detection: Optical detection
Operator time: 0.5 minutes / assay
Assay duration: 15 minutes
Sample volume: 10 ml, including volume for cleanup
Sample injection: 10 or 20 ml disposable syringes
Cleaning: Self-cleaning operation – No cleaning required
Display: 7.4″
Calibration: Automatic temperature calibration routine.
Possibility to enter temperature correction table at 10°C intervals. Programmable calibration frequency.
Memory: 50 last results, unlimited connected to PC
Data output : 2 x USB
1 x Series
1 x Ethernet
Dimensions (W x D x H): 250 x 60 x 27 Cm
Weight: 25 kg
Power supply: 100 – 240V; 200W; 50/60 Hz
Crystallization Point (Freezing Point)
According to standards: ASTM D7153 – IP529 – DEF STAN 91-91
Correlation with: ASTM D2386 – IP16 – ISO3013 – JIS K2276
Certified patterns for crystallization point
Bar code scanner for sample number entry
Syringes
Certified temperature probe
Ethernet cable
RS232 cable
Other accessories, Consult us
Pide información de Automatic crystallization point analyzer (Freezing Point) model OptiFZP
We want to play an active role in creating a safer and more environmentally respectful future.
Related resources
Dew Point measurement: how to control residual moisture in industrial processes
Continue reading
Our thanks for the Marta Mayordomo Award
Continue reading
New reference standards certified at –40 °C for Jet Fuel testing
Continue reading
InnovaPrep solutions for microbiological detection in critical environments
Continue reading
ASTM D93-25: Standard update to improve traceability of the flash point
Continue reading
High-precision temperature control with a commitment to the environment
Continue reading