Analyzer for Sulfur in Petroleum Products R Series, model R1

Description

Specifications

Parameters

Standards

Accessories

Descargas

Videos

New sulfur analyzer model SINDIE R1, with Accucell sample cup. Fully automatic results in 5 minutes with a single keystroke.
According to standards: ASTM D7039 - ISO 20884 - ASTM D2622 - EN 16997
Test method: MWDXRF - Monochromatic Wavelength Dispersive X-Ray Fluorescence™. Characteristics:
  • LOD (Limit of Detection): 0.7 mg/kg (ppm) at 300 s, 0.5 mg/kg (ppm) at 600 s.
  • Low and high range available:
    • Low range: 0.7 mg/kg (ppm) - 3000 mg/kg (ppm)
    • High range: 0.3 % wt.% - 10 % wt.%.
  • Intuitive 10-inch touch screen.
  • Measuring time: 10-999 s.
  • Low maintenance: no gases, heating elements, columns or quartz tubes.
  • Sample cups available:
    • Traditional 43 mm XRF.
    • Accucells
  • LIMS integration for data management and transfer.
  • Customized sample presets.
  • Storage capacity: more than 50,000 results.
  • Supports up to 30 calibration curves.
  • USB connectivity.
Applications:
  • Petroleum products (diesel, jet, kerosene, other distillates, naphtha, residual oil, lubricating base oil, hydraulic oil, fuel oils, crude oil, gasoline, gasoline-ethanol blend, coal and petroleum coke).
  • First and second generation biofuels (biodiesel, ethanol, renewable diesel, HVO, SAF).
  • Oils and fats (edible) (UCO, tallow, palm oil, corn oil, soybean oil, etc.).
  • Chemical products (toluene, xylene, methanol, benzene, etc.).
  • Aqueous matrices.
  • Minimum sample volume:
    • Traditional cup: 5 mL
    • Accucells: 1 mL
  • Optimized software and firmware.
  • Multipoint calibration.
  • 10″ color touch screen, with guided software for calibration, measurement and service.
  • Printer(optional), possibility of printing calibration data including graphs and linear and quadratic regression line.
  • Dimensions: 42 cm (height) x 40 cm (width) x 54 cm (depth)
  • Power supply: 200-240 VAC, 47-63 Hz
  • Wavelength: Vacuum
  • Excitation source: Cold air 75W


LOD:
0.5 ppm
(Detection limit)

Repeatability: 95% confidence
0.9 ppm to 10 ppm
3.0 ppm to 100 ppm
8.0 ppm to 1000 ppm
80 ppm to 10000 ppm (1% wt)
Dynamic range: 0.5 ppm to 10% wt

Sulfur

ASTM D7039
ISO 20884
ASTM D2622
EN 16997

Calibration standards
Other accessories, Consult us

Pide información de Analyzer for Sulfur in Petroleum Products R Series, model R1

We want to play an active role in creating a safer and more environmentally respectful future.